Induction Heater
| • Working Voltage: 220VAC three phases) 50/ 60 Hz. - • Working Current: 5-25 Amp (30A breaker required)
- • Output Frequency: 50-300 kHz Adjustable
- • Max. Output Power: 10KW
- • Required Water Flowrate: >16 L/min
- • Two Unit: the Power control unit is separated with the induction heating unit
|
Copper Crucible
|
- • Dimensions: 27 mm(OD) x 10 mm(ID) x 12 mm depth
- • Water cooling inside
- • Required Water Flowrate: >40 L/min
- • Max. Load: 5 g for metallic or alloy
- • Required water: > 40 L/min.
|
Optional Recirculating Water Chiller and Gas required
|
- • If you don't have water cooling line in your lab, please consider our recirculating water chiller
58L/min at extra cost. - • High purity Argon gas ( > 5N) tank with pressure regulator is required, but not included.
Click here to learn more about the installation of a gas regulator. ( please click the picture below right to order a correct gas regulator )
•
|
Quartz Tube & Vacuum Flange |
- • One quartz tube included: 32 mm(OD) x 28 mm(ID) x 160 mm(L
- • One pair of Vacuum Flanges with double high-temperature silicone O-rings
- • Max. Vacuum Pressure:
- • Bottom flange is controlled by an electric motor for easy sample loading and unloading
|
Vacuum Pump
|
- • One two-stage mechanical pump with exhaust filter is included
- • KF25 adapter, bellow, and valve are included for immediate use
- • The vacuum pump is integrated into the movable steel case
- • .
|
Product Dimensions | 450 mm(L) x 950 mm(W) x 1485 mm(H) |
Warranty | One Year limited warranty with lifetime support |
Application Notes |
- • The Melting System are designed for using under vacuum and low pressure < 0.02 MPa / 0.2
Bar/ 3 PSI - • Attention: A pressure regulator must be installed on your input gas tank ( click picture below to
review ) and have the output gas pressure set below 3 PSI at all times after opening the gas tank with the gas maintained in a continuous flowing condition. Gas build-up with pressure levels exceeding over 3 PSI may cause irreversible damage to the furnace chamber. - • Never heat the furnace while the gas release valve is closed and a positive pressure condition
exists within the furnace chamber. The pressure gauge must be used to closely monitor the chamber condition at all times during the heating process; please open the gas release valve immediately once the chamber pressure has reached over 3 PSI to prevent unforeseeable damages. - • The flow rate for gases should be limited to < 200 SCCM ( or 200ml/min )
- • WARNING
Understand the standard procedure for vacuum melting and inert gas melting prior to operation. Read the manual carefully. Monitor and control the inside pressure of the reaction vessel at all time during operation. Otherwise, failure of operation may result in irreparable damage to the equipment or personal injury. - • For customization inquiries, please complete the "Customize Induction Heating System Form"
and return it to info@mtixtl.com
|
Compliance | NRTL or CSA Certification is available upon request at extra cost |
Operation Manual & Video |
|
Net Weight | 120 kg |