Compact Levitation Cold Crucible Vacuum Melting Furnace(10KW, 5g Max.) -- EQ-FMF-10

Compact Levitation Cold Crucible Vacuum Melting Furnace(10KW, 5g Max.) -- EQ-FMF-10

기본 정보
Product Name Compact Levitation Cold Crucible Vacuum Melting Furnace(10KW, 5g Max.) -- EQ-FMF-10
Sale Price Call for Price
Product Code EQ-FMF-10
Quantity 수량증가수량감소
상품 옵션
 
EQ-FMF-10 is a compact Vacuum Float-Melting System for exploring new generation magnetic alloy and metallic materials. The system uses a 10KW high-frequency induction heater to make metallic sample ( 5g max) melting by magnetic vortex within a special designed water-cold copper crucible placed inside a vacuum-sealed quartz tube. Therefore, it can produce extra high purity metallic alloy without any contamination.
 
SPECIFICATIONS:


Induction Heater

 

  •      •  Working Voltage: 220VAC  three phases)   50/ 60 Hz.
  •      •  Working Current: 5-25 Amp (30A breaker required)
  •      •  Output Frequency: 50-300 kHz Adjustable
  •      •  Max. Output Power: 10KW
  •      •  Required Water Flowrate: >16 L/min
  •      •  Two Unit: the Power control unit is separated with the induction heating unit


Copper Crucible



  •      •  Dimensions: 27 mm(OD) x 10 mm(ID) x 12 mm depth
  •      •  Water cooling inside
  •      •  Required Water Flowrate: >40 L/min
  •      •  Max. Load:  5 g for  metallic or alloy
  •      •  Required water: > 40 L/min.


Optional

Recirculating Water Chiller
and  Gas required


  •      •  If you don't have water cooling line in your lab, please consider our recirculating water chiller
           58L/min at extra cost.
  •      •  High purity Argon gas ( > 5N) tank with pressure regulator is required, but not included.
            Click here to learn more about the installation of a gas regulator. ( please click the picture
            below right to order a correct gas regulator )

     •                        


Quartz Tube &
Vacuum Flange

  •      •  One quartz tube included: 32 mm(OD) x 28 mm(ID) x 160 mm(L
  •      •  One pair of Vacuum Flanges with double high-temperature silicone O-rings
  •      •  Max. Vacuum Pressure:
  •      •  Bottom flange is controlled by an electric motor for easy sample loading and unloading

                        


Vacuum Pump

 

    •      •  One two-stage mechanical pump with exhaust filter is included
    •      •  KF25 adapter, bellow, and valve are included for immediate use
    •      •  The vacuum pump is integrated into the movable steel case

    •      •                     .

    Product Dimensions450 mm(L) x 950 mm(W) x 1485 mm(H)
    WarrantyOne Year limited warranty with lifetime support

    Application Notes

    •      •  The Melting System are designed for using under vacuum and low pressure < 0.02 MPa / 0.2
               Bar/ 3 PSI
    •      •  Attention: A pressure regulator must be installed on your input gas tank ( click picture below to
              review ) and have the output gas pressure set below 3 PSI at all times after opening the gas
               tank with the gas maintained in a continuous flowing condition. Gas build-up with pressure
              levels exceeding over 3 PSI may cause irreversible damage to the furnace chamber.  
    •      •  Never heat the furnace while the gas release valve is closed and a positive pressure condition
              exists within the furnace chamber. The pressure gauge must be used to closely monitor the
              chamber condition at all times during the heating process; please open the gas release valve
              immediately once the chamber pressure has reached over 3 PSI to prevent unforeseeable
              damages.
    •      •  The flow rate for gases should be limited to < 200 SCCM ( or 200ml/min )
    •      •   WARNING  
               Understand the standard procedure for vacuum melting and inert gas melting prior to
               operation. Read the manual carefully. Monitor and control the inside pressure of the reaction
               vessel at all time during operation. Otherwise, failure of operation may result in irreparable
               damage to the equipment or personal injury.
    •      •  For customization inquiries, please complete the "Customize Induction Heating System Form"
              and return it to info@mtixtl.com

    Compliance       NRTL or CSA Certification is available upon request  at extra cost

    Operation Manual & Video
         
      
            

    Net Weight120 kg