Test Chamber Features | - SS 304 stainless steel double-layer chamber with foam polyurethane and fiberglass as the thermal insulator
- Anti-explosion LED light (30W) is installed inside
- A venting port with a high-quality exhaust fan is installed in the back of the chamber connected to the site venting system (ducting and exhaust system are not included )
- LPG gas source is required (but not included); bunsen burner; flamming time and height adjustable
- LPG gas detector and the alarm system are included for safe operation; If the system detects the leakage, the gas delivery valve would be shut off automatically.
- The sample testing stage with steel & aluminum screen to follow the UL 1624 section 19.3 testing standards
|
Power | - AC 208 - 240 single phase 50/60 Hz
- Maximum 500 W
|
Lithium batteries | - Coin cells
- Cylindrical cells
- Pouch cells
- Prismatic cells
|
Burning & Flamming | - Gas: LPG; Liquefied petroleum gas is required but not included.
- Burner: Bunsen burner with 9.5 mm diameter and 100 mm length
- Automatic lighting
- Flamming time: 0 - 999 seconds adjustable
- Flamming height: 10 - 75 mm
- Steel screen: 0.45 mm diameter; 20 mesh
- Aluminum screen: 0.25 diameter; 16 mesh
|
Mobility | - Four mobile wheels are installed at the bottom for easy transportation
|
Net weight & dimension | - 357 kg (787.05 lbs)
- 1,020 mm (L) x 980 mm (W) x 1,865 mm (H)
|
Warranty | - One-year limited manufacturer's warranty with lifetime support
- Extended warranty available upon request at additional cost
|
Optional | - High-resolution camera monitoring
- Class D Lithium battery fire extinguisher
|
Instruction & demo | |
Application notes | |